FEATURES |
· Microprocessor Based with Printer Interface · Auto Gas Cutoff (Model - 1385) · Auto Flame Failure Detection (Model - 1385) · Four Measurements in Single Aspiration · Setup Storage Facility · Sample Data Storage Facility · Curve Calibration Programmability Using Maximum of 5 Standards · Multiple Calibration Curve Saving Facility · Data Processing Through Curve Fitting Techniques, Least Square, Quadratic · Online Help Key · Direct Results in ppm and meq · Useful for Medical & Soil Testing |
Microprocessor Flame Photometer - 1385 comes with flame failure detection and auto gas cutoff facility. In case of power failure, the gas cuts off automatically. In case the flame goes off accidently during work, the flame failure alarm sounds after few seconds
Microprocessor Flame Photometers - 1385 & 1382 are used for the determination of sodium, potassium, calcium and lithium. They uses the latest microcontroller technology and advanced engineering techniques so as to give enhanced and reproducibility. They have soft touch membrane key for ease of operations.
The sample solution is aspirated through an automiser. Sample, Air and the fuel are mixed in the mixing chamber which is then sprayed as a very fine mist into the flame. The color of the flame is changed depending upon the concentration of elements present. Radiations from the flame passes through the sensing system and specific narrow band interference filter which permits only the characteristic radiation to pass to the photo-detector. The output of the photo-detector is then processed by the microcontroller and the final results are displayed on the 20 x 4 line alphanumeric lcd with backlit.
In both models 5-Point calibration facility and non-linearity correction is provided through an automatic curve fitting software. Facility has been provided for re-standardization with a single standard, thereby, eliminating the need of the multiple standards once a calibration has been performed.
SPECIFICATIONS:-
Mode | General | Serum | Urine |
Range | Na: 0 - 100 ppm | Na: 0 - 200 | Na: 0 - 250 |
Sensitivity | General: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm | ||
Filters | Na & K supplied (Ca & Li are optional at extra cost) | ||
Resolution | 0.1 ppm/meq | ||
Reproducibility | < 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as maximum standard | ||
Curve Fit Accuracy | < 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum standards | ||
Display | 20 x 4 alphanumeric LCD with backlit | ||
Average Time | In-built in software | ||
Flame System | LPG and dry oil free air | ||
Detector | Silicon photodiode | ||
Calibration | Upto 5-Point calibration with curve fitting software | ||
Gas Control | Adjustable with knobs | ||
Flame Failure | Auto detection (Model - 1385) | ||
Gas Cuttoff | Automatic (Model - 1385) | ||
Ignition System | Auto ignition | ||
Automiser | Axial flow type | ||
Printer | Provision for attachment of dot matrix printer or HP laserjet/ inkjet (non-windows) printers with centronics parallel interface | ||
RS-232C | Available (PC software at extra cost) | ||
Power | 230 V + 10% AC, 50 Hz | ||
Dimensions | 285 x 255 x 210 mm (L x B x H) (Approx.) | ||
Weight | 7.5 Kg (Approx.) | ||
COMPRESSOR UNIT | |||
Air Supply | By oil free mini compressor unit with pressure regulator | ||
Combustion Gas | LPG controlled by precision regulator | ||
Power | 230 V + 10% AC, 50 Hz | ||
Dimensions | 290 x 255 x 210 mm (L x B x H) (Approx.) | ||
Weight | 8 Kg (Approx.) |
|
SINGHLA SCIENTIFIC INDUSTRIES
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |